Skip to content
Esperto Engineers

Solar PV Audit & Inspection

Assess. Identify. Optimize. A performance and safety inspection that shows what's really happening in your plant, whoever installed it.

What your plant gains

Know exactly what to fix, and in what order

Find hidden losses

Identify where your plant may be losing generation.

Spot costly faults early

Heating, wiring and earthing problems, caught in time.

Fix the right things first

Every issue ranked by risk and urgency.

Why audit

Why every solar plant needs a health check

A solar plant keeps generating even when something is wrong. Heat, dust and years of operation quietly reduce its output and its safety.

Where plants quietly lose value

Hotspots & loose connections

Loose terminals, damaged cells and worn connectors resist current and heat up. The fault grows quietly with every heating and cooling cycle.

Impact: Fire risk, burnt equipment and forced shutdowns.

Soiling & shading

Dust, bird droppings, new structures or vegetation block light from reaching the cells. In dusty conditions this builds up fast.

Impact: Units lost every day, often blamed on the weather.

String mismatch & module damage

A cracked, delaminated or degraded module drags down its whole string, even when the other modules are healthy.

Impact: Lower output and faster ageing of the array.

Inverter faults & derating

Repeated alarms, overheating or blocked ventilation make the inverter cut its output while the plant still appears to run.

Impact: Capped generation that nobody notices on the display.

Cable & insulation wear

UV, heat and mechanical stress crack cable insulation and loosen connectors over time, on both the DC and AC sides.

Impact: Earth faults, arcing risk and unplanned downtime.

Earthing & protection gaps

Corroded bonds, missing links or ageing surge protection leave the plant exposed to faults and lightning.

Impact: Danger to people, damaged equipment and insurance exposure.

Small losses add up

What could your plant be losing?

Every 1% of output lost on a 500 kWp plant is about 7,500 kWh a year. Adjust the sliders for your own plant.

500 kWp
1 %
1,500 kWh/kWp
45 Rs/kWh

Generation lost every year

7,500 kWh

Value lost every year

Rs 337,500

Illustrative estimate only. Actual figures depend on site, irradiance, tariff and the faults found. Savings are not guaranteed.

When to audit

Every year, before the defects liability period ends, when output drops, or after storms and heavy dust.

Which plants

Industrial, commercial and rooftop solar plants, whoever installed them.

What we inspect

What we inspect, area by area

We agree the scope before the visit and tailor it to your plant.

PV modules & structure
  • Cracks, damage, discoloration, soiling
  • Shading, clamps, fasteners, frames
  • Delamination, backsheet, junction boxes
DC system & strings
  • String voltage and current, safely accessed
  • Cables, connectors, polarity, insulation
  • Combiner boxes, fuses, protection
Inverters & AC system
  • Alarms, fault history, parameters
  • Breakers, isolators, terminations
  • Ventilation, cooling, grid status
Thermal inspection
  • Hotspots at modules and connections
  • Panel and breaker terminations
  • Compared with neighbours, photographed
Earthing & protection
  • Earthing conductors and bonding
  • Structure and frame bonding
  • Surge and lightning protection
Performance review
  • Irradiance and module temperature
  • Reported vs. expected output
  • Monitoring and data logging
Thermal camera, clamp meters, insulation tester and irradiance meter used in PV audits

Professional-grade instruments

Thermal imaging cameras, clamp meters, insulation resistance testers and irradiance meters, used safely by trained engineers.

Safety first

PPE and insulated tools, lockout/tagout, and measurements only at safe, accessible points.

Add-on tests

I-V curve tracing, power-quality analysis, comprehensive earthing tests and lab module testing.

Process & report

From site visit to a decision-ready report

  1. 01

    Review

  2. 02

    Inspect & test

  3. 03

    Analyse

  4. 04

    Report

What your report contains

Clear evidence. Clear priorities.

  1. 01Executive summaryA clear one-page overview for management.
  2. 02Findings & loss analysisWhat was seen and measured, with photos and thermal images.
  3. 03Risk-ranked issuesEvery issue rated P1, P2 or P3.
  4. 04Corrective action planWhat to fix, in what order, and why.

Sample report available. Ask us for a sample audit report to see exactly how findings, photos, priorities and actions are presented.Ask us for one.

How we rate every issue

Every finding gets a priority

P1

Act immediately

Safety risk or serious fault. Do not delay.

P2

Plan & schedule

Real generation loss or a deteriorating condition. Fix in the next maintenance window.

P3

Monitor

Minor item. Recheck at the next visit.

Reference frameworks: IEC 62446-1, IEC 61724, IEC 62548 (reference only; no certification implied). Conclusions reflect the conditions and access available during inspection. Energy savings are not guaranteed. Repairs, replacements, cleaning and add-on tests are excluded unless agreed in writing.

FAQ

Solar PV audit FAQs

Can't find your answer? Contact our team.

Do you audit plants that Esperto did not install?

Yes. We audit industrial, commercial and rooftop solar plants regardless of who installed them.

Does the plant need to shut down during the audit?

No, most checks are carried out while the plant is running. Some measurements need short, planned isolation of individual strings or inverters, which we agree with your team in advance.

How long does an audit take?

It depends on plant size and the agreed scope. A typical commercial plant takes one to two days on site, followed by analysis and the written report.

How often should a plant be audited?

We recommend an audit every year, before the defects liability period ends, whenever output drops, and after storms or heavy dust.

What should we prepare before the visit?

Single-line diagrams, commissioning records and generation data help us most, where available. We also need safe access to the array, combiner boxes and inverter room.

Can I see a sample report first?

Yes. Ask us for a sample audit report to see exactly how findings, photographs, priorities and actions are presented.

Schedule your solar audit

Tell us about your plant

Share your plant size and location. We'll propose a tailored scope and inspection schedule.

Contact details

Speak directly with our engineering and advisory team.

Follow Us

Request a PV Audit

Share your plant specifications for a tailored audit schedule.

We only use your details to respond to this enquiry. See our privacy policy.