Hotspots & loose connections
Loose terminals, damaged cells and worn connectors resist current and heat up. The fault grows quietly with every heating and cooling cycle.
Impact: Fire risk, burnt equipment and forced shutdowns.
Assess. Identify. Optimize. A performance and safety inspection that shows what's really happening in your plant, whoever installed it.

What your plant gains
Identify where your plant may be losing generation.
Heating, wiring and earthing problems, caught in time.
Every issue ranked by risk and urgency.
Why audit
A solar plant keeps generating even when something is wrong. Heat, dust and years of operation quietly reduce its output and its safety.
Loose terminals, damaged cells and worn connectors resist current and heat up. The fault grows quietly with every heating and cooling cycle.
Impact: Fire risk, burnt equipment and forced shutdowns.
Dust, bird droppings, new structures or vegetation block light from reaching the cells. In dusty conditions this builds up fast.
Impact: Units lost every day, often blamed on the weather.
A cracked, delaminated or degraded module drags down its whole string, even when the other modules are healthy.
Impact: Lower output and faster ageing of the array.
Repeated alarms, overheating or blocked ventilation make the inverter cut its output while the plant still appears to run.
Impact: Capped generation that nobody notices on the display.
UV, heat and mechanical stress crack cable insulation and loosen connectors over time, on both the DC and AC sides.
Impact: Earth faults, arcing risk and unplanned downtime.
Corroded bonds, missing links or ageing surge protection leave the plant exposed to faults and lightning.
Impact: Danger to people, damaged equipment and insurance exposure.
Small losses add up
Every 1% of output lost on a 500 kWp plant is about 7,500 kWh a year. Adjust the sliders for your own plant.
Generation lost every year
7,500 kWh
Value lost every year
Rs 337,500
Illustrative estimate only. Actual figures depend on site, irradiance, tariff and the faults found. Savings are not guaranteed.
Every year, before the defects liability period ends, when output drops, or after storms and heavy dust.
Industrial, commercial and rooftop solar plants, whoever installed them.
What we inspect
We agree the scope before the visit and tailor it to your plant.

Thermal imaging cameras, clamp meters, insulation resistance testers and irradiance meters, used safely by trained engineers.
PPE and insulated tools, lockout/tagout, and measurements only at safe, accessible points.
I-V curve tracing, power-quality analysis, comprehensive earthing tests and lab module testing.
Process & report
What your report contains
Sample report available. Ask us for a sample audit report to see exactly how findings, photos, priorities and actions are presented.Ask us for one.
How we rate every issue
Safety risk or serious fault. Do not delay.
Real generation loss or a deteriorating condition. Fix in the next maintenance window.
Minor item. Recheck at the next visit.
Reference frameworks: IEC 62446-1, IEC 61724, IEC 62548 (reference only; no certification implied). Conclusions reflect the conditions and access available during inspection. Energy savings are not guaranteed. Repairs, replacements, cleaning and add-on tests are excluded unless agreed in writing.
Yes. We audit industrial, commercial and rooftop solar plants regardless of who installed them.
No, most checks are carried out while the plant is running. Some measurements need short, planned isolation of individual strings or inverters, which we agree with your team in advance.
It depends on plant size and the agreed scope. A typical commercial plant takes one to two days on site, followed by analysis and the written report.
We recommend an audit every year, before the defects liability period ends, whenever output drops, and after storms or heavy dust.
Single-line diagrams, commissioning records and generation data help us most, where available. We also need safe access to the array, combiner boxes and inverter room.
Yes. Ask us for a sample audit report to see exactly how findings, photographs, priorities and actions are presented.
Schedule your solar audit
Share your plant size and location. We'll propose a tailored scope and inspection schedule.
Speak directly with our engineering and advisory team.

Electrical, mechanical, and harmonic audits to eliminate energy waste and cut costs.

Turnkey EPC, tier-1 solar installation, and flexible financing for industrial power.

Utility-scale lithium BESS for reliable backup, peak shaving, and 24/7 power.